High-tech at every step

SRS 10 Low Pressure Standard Level Switch

General Description

SRS level switches are used for tank level measurement and control. It is preferred with the advantages of high temperature resistance, long-lasting contact structure that can work in all directions, stainless steel wet parts, and vertical or horizontal connection.

Technicial Specifications

  • In our SRS 10 series, the mounting method must be positioned horizontally. Flange material 316 Pas. It is steel. Float material 316 Pas. It is steel.
  • Our ambient temperature is (-)20°C…(+)80°C.
  • Max at SRS 10 The pressure is 16 bars and the temperature is 150°C. The float test pressure is 25 bar.
  • In our SRS10x model, the entire housing is made of 304 Rust. It is steel.
  • In our SRS 11 AND 12 series, Max. The pressure is 25bar and the temperature is 250°C. Float Test Pressure is 40 bars.
  • Housing: Aluminium.